Multicon dust arresters are designed to filter gas from mechanical particles and condensate and provide filtering fineness starting from 40 μm. The collectors may be used as a part of various skids and assemblies, such as startup and instrument gas treatment plants, booster compressor stations, block and gas pressure control valves. Dust collectors themselves are vertical makes with multicyclone dust catches placed on top and operation philosophy based on having the gas flow through flow swirls (cyclones) at high speed and consequently having particles and mist separated from gas.
Factor |
DN 300 |
DN 400
|
DN 700
|
DN 800
|
DN 1000
| |
---|---|---|---|---|---|---|
Pressure, MPa |
operating |
5.5 (7.5) | ||||
test |
7.1 (9.7) | |||||
Fluid |
natural gas | |||||
Voume, m3 |
0.1 |
0.21
|
0.67
|
0.929
|
1.4
| |
Flow, thousand m3/hr
|
10…50
|
20…63
|
40…125
|
50…160
|
60…200
| |
Dimensions, mm |
Length |
530 |
870
|
1075
|
1070
|
1815
|
Width |
660 |
720
|
970
|
1200
|
1270
| |
Height |
1710 |
1955
|
2375
|
2390
|
2405
|
Available options:
- other operating pressures, volumes and typical dimensions;
- other quantities and dimensions of connections;
- extra instruments and valves;
- electric heating for dust arrester casing;
- with or w/o supports;
- climate design U (up to minus 40°С) and UKhL (up to minus 60°С);
- extra maintenance platforms;
- dust arrester casing heat-insulation or
- corrosion-proofing.